Test reports VANDEX CEMLINE MORTAR
Test report no. 09-055/01
2007 Austria
Institute:
Österreichische Vereinigung für das Gas- und Wasserfach ÖVGW
Content:
Potable water compatibility
Test report no. 01-077/02
2005 Germany
Institute:
Hygiene Institute of the University of Bonn
Content:
Microbiological growth
Potable water compatibility
Slime formation
DVGW W 270
Test report no. 01-100/02
2005 Germany
Institute:
Hygiene Institute of the Ruhrgebiet, Gelsenkirchen
Content:
TOC
Organoleptic test
Potable water compatibility
Chromium and lead extraction
DVGW W 347
Test report no. 01-100/03
2005 Germany
Institute:
Hygiene Institute of the Ruhrgebiet, Gelsenkirchen
Content:
Potable water compatibility
DVGW W 347
Test report no. 01-152/00
2005 Germany
Institute:
Universität Rostock, Institut für Bauingenieurwesen, Fachgebiet Baustoffe
Content:
Air content
Test report no. 01-140/04
2004 Germany
Institute:
Fakultät für Ingenieurwissenschaften, Fachbereich Bauing.wesen, Fachgebiet
Baustoffe, Universität Rostock
Content:
Porosity
Test report no. 01-170/00
2003 Germany
Institute:
Official Materials Testing Institute Clausthal-Zellerfeld
Content:
Water vapour diffusion
Test report no. 01-128/00
2002 Germany
Institute:
Official Materials Testing Institute Clausthal-Zellerfeld
Content:
Mechanical properties
Bending tensile strength
Compressive strength
Adhesion strength
Density of wet mix
Consistency
Air content
Test report no. 01-062/00
1996 Germany
Institute:
Official Materials Testing Institute Clausthal-Zellerfeld
Content:
Mechanical properties
Bending tensile strength
Compressive strength
Modulus of elasticity
Adhesion strength